Ucam Pcb Software

Posted by admin- in Home -14/09/17

Search Strain Gauges by Category. Click Type or Operating Temperature. You can review available types or operating temperature ranges. To narrow down the selection range, click Gage Pattern, Gage Length or Gage Resistance in Further narrow down. Strain Gauges Accessories. Issuu is a digital publishing platform that makes it simple to publish magazines, catalogs, newspapers, books, and more online. Easily share your publications and get. Strain gauges are described in details. Products Search from product category Strain Gauges Customized Strain Gages. PCB,PCB EDA,PCB CAM,PCB Design Software,PCB Download,edaPCB,Gerber CAM,PCB ICT,PCB,PCB,PCB. Ucamco invites customers and prospects to its booth at Productronica 2017 to see the latest developments of their products for the PCB manufacturing industry. Reset. Type. 00 gages are found. General stress measurement. High temperature. Low temperature. Waterproof. High elongation strain. Concrete. Composite material. Printed board. Plastics. Bolt axial tension. High electric field. High magnetic field. Hydrogen. Highly sensitive semiconductor. Ucam Pcb Software' title='Ucam Pcb Software' />Ucam Pcb SoftwarePCB,PCB EDA Gerber CAM,Genesis2000,PCB,PCB,Cadence,PCB,PCB,PCB,PCB,PCB,PCB. Watch vintage hairy porn sex movie free porn video on MecVideos. Ucam Pcb Software' title='Ucam Pcb Software' />Residual stress. Crack. Internal stress. Bending strain. Weldable. Thermocouple equipped. Operating Temperature. Ucam Pcb Software' title='Ucam Pcb Software' />High temperatures 3. High temperatures 1. Chief Architect 97 Crack there. Normal to MidHigh Temperatures. Low temperature 4. Ultra low 2. 69 to 0Result of narrowing down the selection range 0. Reset. Further narrow down the selection range. Gage Patterns. Uniaxial. Biaxial. 35 element. Biaxial torques. Special. Gage lengths. Shorter than 1 mm. Gage resistances. Product image. Type. Description. KFGS Series. General purpose Foil Strain Gages. New strain gages with the world highest level performance. Click here for the Typical Strain Gauge Bonding ProcedureKFG Series. General purpose Foil Strain Gages. The KFG series gages use polyimide resin for the base part that is approx. It ensures excellent flexibility. The outstanding moisture proof enables the KFG gages to operate in outdoor measurement effectively. Unless directly exposed to water drop, no coating treatment is required. Click here for the Typical Strain Gauge Bonding ProcedureClick here for the Strain Gages with Pre attached Lead CablesKFGSKFGS for Residual Stress Measurement. KFGS T F7. KFGS gages equipped with a gage terminal enable one touch connectiondisconnection of the lead wire cable. They are suitable for residual stress measurement with the cutting method. A clip equipped dedicated cable T C2. Vinyl coated, 2 m long is optionally available. KFGS D2. 8Designed to measure residual stress released by the boring method. KFGKFG for residual stress measurement. KFG T F7. KFG gages equipped with a gage terminal enable one touch connectiondisconnection of the lead wire cable. They are suitable for residual stress measurement with the cutting method. A clip equipped dedicated cable T C2. Vinyl coated, 2 m long is optionally available. KFG D2. 8Designed to measure residual stress released by the boring method. KFG C2. 0KFG for Measuring Axial Tension of Bolts. If it is difficult to bond a strain gage to the surface of a bolt for measuring the tightening stress, these gages enable the measurement by embedding into a hole, 2 mm diameter, bored from the top head of the bolt. They are applicable to materials having a linear expansion coefficient of 1. C. KFGT Series. Foil Strain Gages with Temperature Sensor. The KFGT gages are foil strain gages incorporating a T type thermocouple for simultaneous measurement of strain and temperature. They ensure not only efficient strain measurement under environments where temperature change or temperature gradient requires simultaneous measurement of strain and temperature but also highly precise compensation of thermally induced apparent strain. It is recommended to use KYOWA data logger UCAM 6. B as a mating instrument. KFR Series. Foil Strain Gages. The KFR series foil strain gages are durable and easy to use high grade strain gages. The gage element is sandwiched between heat resistant polyimide base and cover, thereby letting them exhibit high performance in a wide temperature range. Click here for the Typical Strain Gauge Bonding ProcedureClick here for the Strain Gages with Pre attached Lead CablesKFWB Series. George Winston Autumn Zip. Waterproof Foil Strain Gages. The KFWB seres foil strain gages have the surface covered with a special resin for waterproofing. The waterproof structure enables these gages to serve for outdoor or underwater measurement merely by being bonded to measuring objects. The insulation resistance shows virtually no deterioration even after 1. MPa. In addition, the covering resin is flexible enough to enable easy bonding to curved surfaces. Click here for the Strain Gages with Pre attached Lead CablesKFWS Series. Small sized Waterproof Foil Strain Gages. The KFWS series foil strain gages are small sized waterproof gages suitable for outdoor or underwater strain measurement where gage bonding space is limited. The waterproofing resin is as thin as 1. Click here for the Strain Gages with Pre attached Lead CablesKFVFoil Strain Gage for Hydrogen Gas Environment. KFV is a foil strain gage that enables stable strain measurement under high pressure hydrogen gas environment. The metal foil of conventional foil strain gages has the electric resistance changed by receiving hydrogen effect, thereby disabling stable strain measurement. KFV strain gage receives less electric resistance change due to hydrogen, thereby enabling stable strain measurement. KCW Series. Weldable Waterproof Foil Strain Gages. The KCW foil strain gage are weldable gage, which does not require any coating treatment for use under high pressure or under water. They are available in 2 types G1. G1. 4S with 4 gages. The G1. 0 type endures a water pressure of approximately 1. MPa. KFGSKFGS for Concretes. Listed here are the KFGS series gages with a suitable lead wire cable for strain measurement of concrete. KFGKFG for Concretes. Listed here are the KFG series gages with a suitable lead wire cable for strain measurement of concrete. Click here for the Strain Gages with Pre attached Lead CablesKC Series. Wire Strain Gages. Featuring a longer gage length, the KC series gages are wire strain gages suitable for mean strain measurement of concrete under test. Ja News Ticker Module. Usually, a model with the gage length over 3 times longer than the maximum diameter of the aggregate is selected for the purpose. Click here for the Strain Gages with Pre attached Lead CablesKM Series. Embedded Strain Gages. The KM series gages are designed to be embedded in mortar or concrete for the purpose of measuring the internal stress. To ensure better adhesion to mortar or the like, the KM series gages feature a specially treated surface. They also provide suitable waterproofness and elastic modulus for the intended purpose. Click here for the Strain Gages with Pre attached Lead CablesKMC Series. Concrete embedded Strain Gages. The KMC series gages are designed to measure self shrinkage and self stress of cemented materials. They enable measurement of the self shrinkage and high fluidity concrete immediately after placing. They are also used effectively to check for cracks of cemented materials. Usually, a T type thermocouple is installed near the gage, while the KMC series gages of H4 type do not require such the installation since they are equipped with a built in thermocouple. KFRP Series. Foil Strain Gages for Composite Materials. The KFRP series foil strain gages are self temperature compensation gages SELCOM gages suitable for strain measurement of composite materials such as CFRP and GFRP. The special gage pattern minimizes the effect of self heating due to gage current and the effect of reinforcement of low elasticity materials. To ensure accurate measurement by avoiding the self heating effect of gage current, consider the following 1. Select a lower bridge excitation if the amplifier allows selection. Active dummy method. Click here for the Strain Gages with Pre attached Lead CablesKFRS Series.